Crowcon Xgard – Fixed Gas Detector

111,00 

The Crowcon Xgard is a versatile fixed gas detector range designed for flammable, toxic and oxygen gas monitoring. Available in multiple versions (Types 1–6 and Xsafe), it supports different sensor technologies and hazardous‑area classifications, ensuring reliable gas detection in industrial and marine environments.

The Crowcon Xgard series is a comprehensive family of fixed gas detectors engineered to meet diverse industrial and marine gas‑monitoring requirements. Designed for use in hazardous and safe areas, the Xgard range supports three sensor concepts—intrinsically safe, flameproof, and safe‑area—allowing precise selection based on application and certification needs.

Each Xgard type is optimized for specific gas‑detection tasks:

  • Type 1 & 2 → Toxic gases & oxygen
  • Type 3, 4 & 5 → Flammable gases
  • Type 6 → Thermal conductivity measurement (e.g., CO₂, CH₄ mixtures)
  • Xsafe → Safe‑area flammable gas detection

The rugged construction, wide sensor compatibility, and global approvals make Xgard one of the most widely used fixed gas detectors in oil & gas, marine, wastewater, chemical plants, and manufacturing facilities.

GENERAL FEATURES (ALL XGARD MODELS)

  • Suitable for flammable, toxic and oxygen gas detection
  • Available in intrinsically safe, flameproof, and safe‑area versions
  • Rugged construction for harsh industrial/marine environments
  • Wide range of sensors (pellistor, electrochemical, thermal conductivity)
  • ATEX/IECEx approvals depending on model
  • Multiple housing materials (Nylon, Aluminium, Stainless Steel)
  • Compatible with 3‑wire or 4‑20 mA systems (Type 5)
  • IP65/67 protection depending on configuration

Type 1

Xgard Type 1 – Intrinsically Safe Toxic & Oxygen Detector

 

Parameter Value
Type Xgard Type 1
Classification      Intrinsically Safe (IS)
Gas Types Toxic gases, Oxygen
Sensor Type Electrochemical
Housing Nylon or Aluminium
Certification ATEX/IECEx IS
Output mV (sensor‑driven)
Applications Safe/Zone 0 toxic & O₂ monitoring

Type 2

Xgard Type 2 – Flameproof Toxic & Oxygen Detector

 

Parameter Value
Type Xgard Type 2
Classification      Flameproof (Ex d)
Gas Types Toxic gases, Oxygen
Sensor Type Electrochemical
Housing Aluminium or Stainless Steel
Certification ATEX/IECEx Flameproof
Output mV
Applications Zone 1/2 toxic & O₂ monitoring

Type 3

Xgard Type 3 – Flameproof Flammable Gas Detector

 

Parameter Value
Type Xgard Type 3
Classification      Flameproof (Ex d)
Gas Types Flammable gases
Sensor Type Pellistor (Catalytic bead)
Housing Aluminium or Stainless Steel
Certification ATEX/IECEx Flameproof
Output mV
Applications Hydrocarbon leak detection
 

Type 4

Xgard Type 4 – High‑Temperature Flammable Gas Detector

 

Parameter Value
Type Xgard Type 4
Classification Flameproof (Ex d)
Gas Types Flammable gases
Sensor Type High‑temperature pellistor
Temperature Rating      Elevated (for hot environments)
Housing Aluminium/Stainless Steel
Applications Boiler rooms, engine rooms

Type 5

Xgard Type 5 – Flameproof Flammable Gas Detector (4–20 mA Output)

 

Parameter Value
Type Xgard Type 5
Classification      Flameproof (Ex d)
Gas Types Flammable gases
Sensor Type Pellistor
Output 4–20 mA (active transmitter)
Housing Aluminium/Stainless Steel
Applications PLC/DCS integration
 
 

Type 6

Xgard Type 6 – Thermal Conductivity Gas Detector

 

Parameter Value
Type Xgard Type 6
Classification      Flameproof (Ex d)
Gas Types High‑range gases (e.g., CO₂, CH₄ mixtures)
Sensor Type Thermal Conductivity (TC)
Housing Aluminium/Stainless Steel
Applications Gas mixtures, high‑concentration gases
 
 

Xsafe

Xsafe – Safe‑Area Flammable Gas Detector

 

Parameter Value
Type Xsafe
Classification      Safe Area
Gas Types Flammable gases
Sensor Type Pellistor
Housing Nylon
Certification Non‑hazardous area
Applications Machinery rooms, HVAC, general industry
 
 

Datasheet

Please refer to the Crowcon’s official website for certificates, datasheets and manuals.

SKU: XGARD Categories: , , Brand: